Article 4.9.1A : Why each folder is created per day rather than in one folder ?
Q : The data is getting stored as one folder per day and NOT one folder for all day. So, the report can not be generated for the entire duration of the logging period.
Our latest on site data logging was carried out with the help of your technical support, using WhatsApp video call. The below image shows the total content of the micro SD card:
A : As informed, meter can hold up to 5000 records in a single file. Once it reach the limit, another file will be created & data will save consecutively.
According to site condition, 1 sec (default) interval was set in meter, please set the datalog interval (In meter) to 5 secs or more to overcome this situation.
Note : We can set up to 60 mins log interval.
Related Articles
Article 3.1.125S: Invalid index email error continuous comes in only Day log report.
The below error continuous comes in every second with pop-ups. Other Reports: Invalid index. (Exception from HRESULT: 0x8002000B (DISP_E_BADINDEX)) Other Reports: COM object that has been separated from its underlying RCW cannot be used. To stop ...
Article 3.6.1T : How to copy SQL Data from one table to another table ?
1. SET NOCOUNT ON SET STATISTICS TIME ON INSERT INTO Table_name_one ( colm1, colm2, colm3, colm4, colm5 ) SELECT colm1, colm2, colm3, colm4, colm5, FROM Table_name_two SET STATISTICS TIME OFF SET NOCOUNT OFF Note: Before ...
Article 3.6.1AG : Update query for changing one column data to other column
Please refer the attached document, If a reading is recorded in another column due to wrong config, we can use the query to migrate the data from one column to other
Article 3.6.1O : How to copy one column data to another column in a same table ?
Use below query to copy one column to another column. Syntax: UPDATE Table_Name SET[COLUMN1]=(COLUMN2) WHERE '%CONNDITON%'; UPDATE [ELNetDB_ratan].[dbo].[PPS_Customer] SET[MeterVer]=(Area) WHERE MeterVer='0'; If above query is showing any error ...
Article 3.2.1K : I replaced an existing prepaid meter with new one but couldn't recharge, why?
Once you replace the prepaid meter, you can set the same device ID as before but couldn't recharge the meter. You can't recharge the meter because the new prepaid meter have different serial number. To solve this, Go to customer master, read the ...