Article 2.0.1R : IEC 60529 - IP (Protection standards)

Article 2.0.1R : IEC 60529 - IP (Protection standards)

Ingress Protection (IP) and what it means,

The IP Code (or International Protection Rating, sometimes also interpreted as Ingress Protection Rating*) consists of the letters IP followed by two digits and an optional letter.

As defined in international standard IEC 60529, it classifies the degrees of protection provided against the intrusion of solid objects (including body parts like hands and fingers), dust, accidental contact, and water in electrical enclosures. The standard aims to provide users more detailed information than vague marketing terms such as waterproof.

The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. For example, an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. IP22 or 2X are typical minimum requirements for the design of electrical accessories for indoor use.

*Explanation of the letters IP is given in IEC 60529 (Ed. 2.1), clause 4.1


First Digit: Solids

The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.

LevelObject size protected againstEffective against
0Not protectedNo protection against contact and ingress of objects
1>50mmAny large surface of the body, such as the back of the hand, but no protection against deliberate contact with a body part.
2>12.5mmFingers or similar objects.
3>2.5mmTools, thick wires, etc.
4>1mmMost wires, screws, etc.
5Dust ProtectedIngress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact.
6Dust TightNo ingress of dust; complete protection against contact.

 


 

Second Digit: Liquids

Protection of the equipment inside the enclosure against harmful ingress of water.

LevelObject size protected againstEffective against
0Not protected
1Dripping waterDripping water (vertically falling drops) shall have no harmfull effect.
2Dripping water when tilted up to 15°Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position.
3Spraying waterWater falling as a spray at any angle up to 60° from the vertical shall have no harmful effect.
4Splashing waterWater splashing against the enclosure from any direction shall have no harmful effect.
5Water jetsWater projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.
6Powerful water jetsWater projected in powerful jets (12.5mm nozzle) against the enclosure from any direction shall have no harmful effects.
7Immersion up to 1mIngress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
8Immersion beyond 1mThe equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects.

 


IP Rating Reference Chart

Below is an easy to follow reference chart to help you decide which IP rating you need or have.

IP NumberFirst Digit - SOLIDSSecond Digit - LIQUIDS
IP00Not protected from solids.Not protected from liquids.
IP01Not protected from solids.Protected from condensation.
IP02Not protected from solids.Protected from water spray less than 15 degrees from vertical.
IP03Not protected from solids.Protected from water spray less than 60 degrees from vertical.
IP04Not protected from solids.Protected from water spray from any direction.
IP05Not protected from solids.Protected from low pressure water jets from any direction.
IP06Not protected from solids.Protected from high pressure water jets from any direction.
IP07Not protected from solids.Protected from immersion between 15 centimeters and 1 meter in depth.
IP08Not protected from solids.Protected from long term immersion up to a specified pressure.
IP10Protected from touch by hands greater than 50 millimeters.Not protected from liquids.
IP11Protected from touch by hands greater than 50 millimeters.Protected from condensation.
IP12Protected from touch by hands greater than 50 millimeters.Protected from water spray less than 15 degrees from vertical.
IP13Protected from touch by hands greater than 50 millimeters.Protected from water spray less than 60 degrees from vertical.
IP14Protected from touch by hands greater than 50 millimeters.Protected from water spray from any direction.
IP15Protected from touch by hands greater than 50 millimeters.Protected from low pressure water jets from any direction.
IP16Protected from touch by hands greater than 50 millimeters.Protected from high pressure water jets from any direction.
IP17Protected from touch by hands greater than 50 millimeters.Protected from immersion between 15 centimeters and 1 meter in depth.
IP18Protected from touch by hands greater than 50 millimeters.Protected from long term immersion up to a specified pressure.
IP20Protected from touch by fingers and objects greater than 12 millimeters.Not protected from liquids.
IP21Protected from touch by fingers and objects greater than 12 millimeters.Protected from condensation.
IP22Protected from touch by fingers and objects greater than 12 millimeters.Protected from water spray less than 15 degrees from vertical.
IP23Protected from touch by fingers and objects greater than 12 millimeters.Protected from water spray less than 60 degrees from vertical.
IP24Protected from touch by fingers and objects greater than 12 millimeters.Protected from water spray from any direction.
IP25Protected from touch by fingers and objects greater than 12 millimeters.Protected from low pressure water jets from any direction.
IP26Protected from touch by fingers and objects greater than 12 millimeters.Protected from high pressure water jets from any direction.
IP27Protected from touch by fingers and objects greater than 12 millimeters.Protected from immersion between 15 centimeters and 1 meter in depth.
IP28Protected from touch by fingers and objects greater than 12 millimeters.Protected from long term immersion up to a specified pressure.
IP30Protected from tools and wires greater than 2.5 millimeters.Not protected from liquids.
IP31Protected from tools and wires greater than 2.5 millimeters.Protected from condensation.
IP32Protected from tools and wires greater than 2.5 millimeters.Protected from water spray less than 15 degrees from vertical.
IP33Protected from tools and wires greater than 2.5 millimeters.Protected from water spray less than 60 degrees from vertical.
IP34Protected from tools and wires greater than 2.5 millimeters.Protected from water spray from any direction.
IP35Protected from tools and wires greater than 2.5 millimeters.Protected from low pressure water jets from any direction.
IP36Protected from tools and wires greater than 2.5 millimeters.Protected from high pressure water jets from any direction.
IP37Protected from tools and wires greater than 2.5 millimeters.Protected from immersion between 15 centimeters and 1 meter in depth.
IP38Protected from tools and wires greater than 2.5 millimeters.Protected from long term immersion up to a specified pressure.
IP40Protected from tools and small wires greater than 1 millimeter.Not protected from liquids.
IP41Protected from tools and small wires greater than 1 millimeter.Protected from condensation.
IP42Protected from tools and small wires greater than 1 millimeter.Protected from water spray less than 15 degrees from vertical.
IP43Protected from tools and small wires greater than 1 millimeter.Protected from water spray less than 60 degrees from vertical.
IP44Protected from tools and small wires greater than 1 millimeter.Protected from water spray from any direction.
IP45Protected from tools and small wires greater than 1 millimeter.Protected from low pressure water jets from any direction.
IP46Protected from tools and small wires greater than 1 millimeter.Protected from high pressure water jets from any direction.
IP47Protected from tools and small wires greater than 1 millimeter.Protected from immersion between 15 centimeters and 1 meter in depth.
IP48Protected from tools and small wires greater than 1 millimeter.Protected from long term immersion up to a specified pressure.
IP50Protected from limited dust ingress.Not protected from liquids.
IP51Protected from limited dust ingress.Protected from condensation.
IP52Protected from limited dust ingress.Protected from water spray less than 15 degrees from vertical.
IP53Protected from limited dust ingress.Protected from water spray less than 60 degrees from vertical.
IP54Protected from limited dust ingress.Protected from water spray from any direction.
IP55Protected from limited dust ingress.Protected from low pressure water jets from any direction.
IP56Protected from limited dust ingress.Protected from high pressure water jets from any direction.
IP57Protected from limited dust ingress.Protected from immersion between 15 centimeters and 1 meter in depth.
IP58Protected from limited dust ingress.Protected from long term immersion up to a specified pressure.
IP60Protected from total dust ingress.Not protected from liquids.
IP61Protected from total dust ingress.Protected from condensation.
IP62Protected from total dust ingress.Protected from water spray less than 15 degrees from vertical.
IP63Protected from total dust ingress.Protected from water spray less than 60 degrees from vertical.
IP64Protected from total dust ingress.Protected from water spray from any direction.
IP65Protected from total dust ingress.Protected from low pressure water jets from any direction.
IP66Protected from total dust ingress.Protected from high pressure water jets from any direction.
IP67Protected from total dust ingress.Protected from immersion between 15 centimeters and 1 meter in depth.
IP68Protected from total dust ingress.Protected from long term immersion up to a specified pressure.
IP69KProtected from total dust ingress.Protected from steam-jet cleaning.

------------------------------------------------------------------------------------------------------- X ------------------------------------------------------------------------------------------------------------

    • Related Articles

    • Article 2.0.1Z : What are the protection standards in Elmeasure meters (MFM)?

      Elmeasure follows the Protection standard as per IEC 60529. IP 51 & IP 54 (Front option). IP51 Protected from limited dust ingress. Protected from condensation. IP54 Protected from limited dust ingress. Protected from water spray from any direction. ...
    • Article : How to find an IP address from a known mac address?

      §  Enter the run command press "Windows + R" wrote "cmd" and then search with"arp -a"' in cmd. §  Use the arp with additional arguments to find the IP within the same network segment. §  With the command “arp -a” you can see the ARP table and its ...
    • Article 4.4.1D : How to reset gateway IP Address to default

      By default, Gateway's IP address is 192.168.5.175. This G/W IP can be changed according to customer's requirements (i.e network range). In some cases, if customer lose the new IP address; they can reset the G/W IP address to default. Please find the ...
    • Article 3.2.1M : How to change logo in Elnet PPS report?

      Go to C:\Program Files\Elmeasure\ElNet PPS\webapps\elnetpps\resources\images (Root folder of Elnet PPS). In Images folder, Replace Logo.jpeg with your logo. Format must be .jpeg & recommended resolution is 403x96. *** End of article *** 
    • Article 1.0.1D : DO's and DONT's for Elmeasure Products

      DO's 1.Always, install safety Equipment's like Earth leakage / overload & short circuit protection [circuit breakers / switches ] near point of supply. 2. Use lugs to connect the electrical wires to the meter while installing. ...